Request for Quotation
LogSol is a unique genset manufacturer concentrating on engineering, manufacturing & supplying custom-made equipment manufactured according to the personal requirements of the customer. Our goal is to develop & promote MAAG brand as a client-oriented equipment & service. We offer you the opportunity to configure your own genset. The below genset configurator saves time for you, and gives us the opportunity to prepare a competitive quotation for a genset you really need.
Please, select requested characteristics!
Notes: Fields marked with * are obligatory to fill in Characteristics marked with (standard) note are default
BASIC INFORMATIONS
Requested genset power*: kVA kW A
Weather & sound proofing: Open type (without proofing) Soundproof canopy 70-75dB(A) (standard level) Soundproof canopy 65-70dB(A) Soundproof canopy 60-65dB(A) Container style enclosure
Definition of requested power type: Standby Power (ESP) Prime Power (PRP) Continuous Power (COP) Datacenter Power
Phase(s): 1 3 (Standard)
Fuel type: Diesel (standard) Gas Petrol
Engine regulation: Unregulated (standard) Stage III Stage V
Exhaust silencer: Standard type Critical type
Additional exhaust chimney method: No chimney (standard) Without fan With fan With Laval-nozzle
Fuel tank capacity at 100% load: No fuel tank 8-hour (standard size) 12-hour 24-hour
Fuel tank location: Integrated between base frames (standard) Integrated inside base frames Separate tank with gravity/suction fuel transfer Separate tank with pump fuel transfer
Load type at client location to be powered: Household Office Animal/fruit farm Production plant Datacenter Health center
Typical load characteristics: Resistive (non-inductive) Inductive, motor with frequency converter Inductive, motor without frequency converter (higher current)
Operation method: Hand operated (standard) AMF for grid power outage Load sharing or peak shaving
AUTOMATIC MAINS FAILURE START FEATURES
Automatic Mains Failure start: Without, hand operated ATS in separate metal cabinet ATS integrated inside genset Remote start functionality (AMF functionality by client)
ATS poles: 3P (standard) 4P
ATS protection: Indoor (standard) Outdoor Fireproof
ATS Mains contactor size: Genset power (A) equivalent Mains power (A) equivalent
ATS control: By genset controller (standard) By integrated AMF controller (sends remote start signal to genset controller)
ELECTRICAL & CONTROL FEATURES
Synchronization function: No With mains With other genset With mains & other genset
Management of client’s motorized circuit breakers for AMF functionality: No (standard) Yes
Remote monitor functionality (additional genset controller): No (standard) Yes (max. 100m cable)
Energy & battery saving (“sleep” status): No (standard) Yes
Genset main circuit breaker: 3P MCB (standard) 3P MCB with shunt unit (additional overload protection) (must have in hand operated) 4P MCB
Electrical socket outlet cabinet: Plastic Metal
Electrical socket outlet cabinet: 1-4 sockets 5-8 sockets
Integrated load bank (to avoid low load pf issues): Yes No (standard)
Lighting tower functionality: No Yes, with electrical socket outlets Yes, with electrical socket and USB outlets Yes, with electrical socket and USB outlets, and WI-FI router
MOBILITY FEATURES
Base frame forklift points: Integrated into base frame Additional brackets under base frame
Lifting/craning points on top of canopy (to lift complete genset): Yes No
Craning ears on base frame: Yes No
Additional lifting frame for craning genset at base frame: Yes No
Integrated spirit level: Yes No (standard)
Trailer functionality: No (standard) Light trailer (Max. 3000kg gross total) pulled by car Semi-trailer pulled by truck Drawbar trailer pulled by truckr
Light trailer (Max. 3000kg gross total) pulled by car versions: Without MOT roadworthiness certificate, with all legal accessories Without MOT roadworthiness certificate, without legal accessories With Hungarian MOT roadworthiness certificate
Remote monitoring functionality: No (standard) Via 2G GSM connection by supervised LogSol Via 2G GSM connection supervised by client Via cable/Ethernet connection at client location Via cable/mod bus connection at client location SNMP